Udp-Galactose 4-Epimerase

(All numbering and residues are taken from first PDB file)

Bending Residue Dihedral Analysis

Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 PRO-139   GLN-140  13.4 13.1 -3.4 5.3 38.8 36.5 -3.7
 GLN-140   TYR-141  13.8 13.4 -4.7 -1.9 94.1 90.5 -27.8
 TYR-141   LEU-142  12.6 12.4 1.1 6.6 26.1 30.5 89.2

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 GLU-146   ALA-147  1.9 1.7 -5.7 4.2 158.7 155.5 -48.3
 ALA-147   HIS-148  2.7 2.5 0.8 4.2 86.3 85.6 34.1
 HIS-148   PRO-149  6.4 6.1 3.7 1.5 79.9 79.5 43.1

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 ARG-184   TYR-185  6.0 5.8 4.3 3.3 38.8 38.8 48.7
 TYR-185   PHE-186  5.3 5.2 -7.5 0.3 87.7 84.5 -18.4
 PHE-186   ASN-187  5.9 5.7 8.0 1.4 29.7 33.0 61.0

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 THR-189   GLY-190  5.7 5.5 -4.3 -0.7 51.6 51.2 94.1
 GLY-190   ALA-191  3.8 3.6 -1.0 -2.3 64.6 63.4 49.7
 ALA-191   HIS-192  2.5 2.3 -0.5 -1.8 76.2 74.9 -33.4

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 CYS-196   ILE-197  5.9 5.6 1.5 -4.4 131.4 129.8 -54.5
 ILE-197   GLY-198  7.2 7.1 4.5 -11.3 121.8 126.7 114.5
 GLY-198   GLU-199  6.9 6.9 -9.1 18.7 61.2 68.1 -113.9
 GLU-199   ASP-200  9.7 9.6 17.7 10.3 50.1 43.3 238.8
 ASP-200   PRO-201  12.9 12.8 -12.6 0.4 60.9 67.8 63.5
 PRO-201   GLN-202  15.9 15.5 -4.9 -13.3 127.1 131.8 -145.2
 GLN-202   GLY-203  19.3 19.1 10.6 -18.3 100.8 105.1 -29.3
 GLY-203   ILE-204  21.4 21.3 -15.1 21.5 85.1 72.3 -60.0
 ILE-204   PRO-205  20.9 21.1 -12.4 -5.1 41.1 40.2 151.7
 PRO-205   ASN-206  17.8 18.0 4.6 6.4 146.3 146.8 -166.8

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 ASP-240   TYR-241  8.5 8.4 -5.1 2.6 39.0 39.4 12.7
 TYR-241   ILE-242  7.3 7.3 -3.3 5.2 87.6 86.8 44.6
 ILE-242   HIS-243  3.6 3.5 -6.5 -1.5 31.8 32.3 65.5

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 TYR-267   ASN-268  4.0 4.1 2.0 0.9 49.8 49.7 87.3
 ASN-268   LEU-269  1.5 1.4 -1.2 5.1 148.0 148.6 21.4
 LEU-269   GLY-270  1.0 1.1 -8.1 5.7 116.7 114.0 -44.2

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 CYS-307   TYR-308  11.8 11.7 -6.8 -2.9 58.1 64.2 51.5
 TYR-308   ALA-309  9.1 9.0 1.4 6.4 47.7 49.4 58.0
 ALA-309   ASN-310  5.9 5.8 -3.8 5.5 109.5 115.0 63.1

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 PRO-311   SER-312  4.2 5.0 -6.1 -3.3 67.4 61.6 73.1
 SER-312   LEU-313  6.7 7.1 -3.5 -4.5 72.5 75.6 -25.8
 LEU-313   ALA-314  5.4 5.7 3.9 -0.1 43.9 40.4 22.1
 ALA-314   GLN-315  5.7 5.8 -4.1 1.5 109.0 109.5 11.4
 GLN-315   GLU-316  8.6 8.8 -1.3 1.9 50.4 53.4 -37.6
 GLU-316   GLU-317  10.3 10.6 -3.3 4.7 86.5 85.6 83.8

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 LEU-318   GLY-319  10.3 10.1 -2.5 5.3 50.1 52.9 -31.3
 GLY-319   TRP-320  11.7 11.7 -6.5 -4.9 30.2 29.6 119.5
 TRP-320   THR-321  8.8 8.9 -2.2 5.1 92.5 90.8 24.8
 THR-321   ALA-322  7.5 7.7 0.7 8.2 156.0 159.4 -134.7
 ALA-322   ALA-323  5.6 5.8 14.4 -24.4 117.4 120.7 134.2
 ALA-323   LEU-324  8.3 8.5 37.6 -34.3 124.2 134.5 -89.1

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 TRP-336   GLN-337  4.7 4.8 -2.2 -2.0 65.4 67.4 34.0
 GLN-337   LYS-338  8.3 8.3 7.3 -6.6 171.9 168.6 -15.4
 LYS-338   GLN-339  7.7 7.9 -1.7 -3.7 57.8 50.8 124.3

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees