Glutathione S-Transferase

(All numbering and residues are taken from first PDB file)

Bending Residue Dihedral Analysis

Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 PRO-109   THR-110  5.0 5.0 2.2 -8.5 103.2 103.1 11.8
 THR-110   MET-111  3.6 3.5 6.9 0.6 103.9 104.6 5.4
 MET-111   ARG-112  1.0 1.0 -4.9 11.9 139.1 143.8 145.9

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 GLY-133   LEU-134  6.7 6.6 2.8 5.5 39.3 43.6 121.9
 LEU-134   VAL-135  4.7 4.7 -4.6 0.9 149.5 148.7 -67.7
 VAL-135   LEU-136  6.3 6.2 -0.4 4.7 89.7 87.8 92.0
 LEU-136   LEU-137  9.6 9.5 -0.5 1.1 102.5 100.4 8.1
 LEU-137   GLU-138  9.3 9.0 -2.8 1.1 159.9 160.3 -47.7
 GLU-138   ASP-139  7.8 7.8 0.6 0.6 58.0 61.3 21.8
 ASP-139   ALA-140  10.7 10.7 2.0 0.3 102.9 105.5 9.2
 ALA-140   PHE-141  13.1 13.1 -2.1 1.7 119.1 120.3 5.1
 PHE-141   SER-142  12.3 12.3 -2.5 4.3 162.6 159.5 7.9
 SER-142   LYS-143  12.4 12.6 -4.0 8.3 94.3 91.2 15.0
 LYS-143   CYS-144  15.9 16.1 -6.4 -0.8 71.9 75.8 -29.7

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 GLY-178   VAL-179  11.8 11.7 3.0 -6.1 125.6 127.7 52.9
 VAL-179   LYS-180  8.6 8.6 3.6 7.3 125.7 124.2 21.6
 LYS-180   LEU-181  6.6 6.6 -8.1 20.1 82.1 88.4 -10.9

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 ASP-183   GLU-184  4.2 3.5 -108.2 124.3 153.7 145.2 347.7
 GLU-184   THR-185  3.1 2.8 -6.5 15.6 119.0 104.1 115.4
 THR-185   ARG-186  2.2 2.2 -2.1 -12.4 58.8 62.3 99.0

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees